Product list category

 Location: Home > Product >   

CN Series

Digital Programmable Time Switch (Panel Mount)

Introduction


  CN series digital programmable time-controlled switches are specially designed for panel-mounting installation. CN series microcomputer time-controlled switches are composed of LCD digital display, programmable IC chips, buttons, switch components, etc., and are widely used in street lights, neon lights, advertising signs, production equipment, assembly lines, broadcast equipment and other equipment. The CN series digital time control switch adopts a brand-new patch technology, which has the characteristics of stable performance, low power consumption and light weight. The CN series has a built-in rechargeable battery, which can save the data for more than 30 days without power supply. The CN series timer switch are divided into CN101A (JFT18) series and CN304 (JFT19) series.

Parameters


CN101A (Panel Mount)

Timer Range: 1min≤t≤168h (cycle work daily or weekly)
Operation Voltage: 220VAC /50Hz (or other customized voltage)
Operation Temperature: -10℃-60℃
Switching Capacity: 16A (resistive load)
Number of Settings: 16 groups per day, with anti-mistouch button lock
Battery: Built-in rechargeable Ni-MH battery
Consumption Power: ≤3W
Weight: 100g
Dimensions: 60×60×30mm
Mounting: Panel/Wall

CN Series CN101A (Panel Mount) image

CN101A (Panel Mount)

Timer Range: 1min≤t≤168h (cycle work daily or weekly)
Operation Voltage: 220VAC /50Hz (or other customized voltage)
Operation Temperature: -10℃-60℃
Switching Capacity: 16A (resistive load)
Number of Settings: 16 groups per day, with anti-mistouch button lock
Battery: Built-in rechargeable Ni-MH battery
Consumption Power: ≤3W
Weight: 120g
Dimensions: 60×60×30mm
Mounting: Panel/Wall

CN Series CN304 (Panel Mount) image

Dimensions & Wiring Diagram


CN Series (Panel Mount)

The installation dimensions and wiring diagram of the CN series timer switch are shown in Figure 1.

CN Series (Panel Mount) dimensions and wiring diagram

CN Series (Panel Mount) dimensions and wiring diagram

Instructions For Use (How to set)


Please make sure that you have understood the functions of all the buttons on the panel (button area), and perform the actual operation according to the instructions.

1 Description of buttons and indicators

CLOCK (): Press to display your local time (it should be set by yourself: you can press and hold the "CLOCK" key to enter the "Time Adjustment Mode", and adjust the "WEEK", "HOUR", and "MINUTE" key to set the local time). PS: If no operation is performed within 30 seconds, the timer switch will automatically display the local time.
TIMER(): Press to enter the "Editing Mode", and then set the time to switch the load by adjusting the "WEEK", "HOUR", and "MINUTE" key.
WEEK (D+): Adjust week or day. There are various working modes, such as "Five-day Mode" (Monday to Friday), "Six-day Mode" (Monday to Saturday), "Weekend Mode" (Saturday, Sunday), "Daily Mode" (Monday to Sunday), and "Three-day Mode" (Mon-Wed-Fri; Tue-Thu-Sat; Mon-Tue-Wed; Thu-Fri-Sat).
HOUR (H+): Adjust hour.
MINUTE (M+): Adjust minute.
AUTO/MANU (MANUAL): Switch the three switching mode of "ON", "AUTO" and "OFF". For multiple-output timer switches, the output combination can be configured through the "AUTO/MANU" key when in the "Editing Mode"
RESET/RECALL (Cancel/Restore, C/R): Press to cancel or restore the timing setting. PS: For products with button lock function, press the " RESET/RECALL " key four times to lock or unlock all buttons.
C: Long press the "C" key to clear all settings of the timer switch.
POWER LED: When the Power LED (red) is on, it means that the timer switch has been successfully connected to the power source.
WORK LED: When the Power LED (red) and the Work LED (green) are on at the same time, it means that the load is powered on.

2 Operating instructions

Step 1. Timing setting (on)

Press the " TIMER " button to enter the "Editing Mode". At this time, the "1ON" symbol will appear at the bottom left of the LCD screen (that is, the first time to turn on the load, as shown in Figure 2), and then press the "WEEK" to select Working Mode, and then press the "HOUR" and "MINUTE" keys to input the required switching on time.

Step 2. Timing setting (off)

Press the " TIMER " button again, the "1OFF" symbol will appear at the bottom left of the LCD screen (that is, the first time to turn off the load, as shown in Figure 3), and then press the "WEEK" to select Working Mode, and then press the "HOUR" and "MINUTE" keys to input the required switching off time. At this time, the first group of timing setting has been completed.

Timing Setting image How to set timer

Timing Setting 1

Step 3. Timing setting (number of groups)

After completing the first group of timing setting, press the "TIMER" button again, the LCD display will show the "2ON" symbol, and you can set the second set of time setting. According to actual needs, you can repeat steps 1 and 2 to set many groups (the maximum programmable group number depends on the product's built-in chip). If you want to exit the “Editing Mode”, you can press the "CLOCK" key to exit it.

Step 4. RESET/RECALL

After setting a group of time, for example, turn on the load at 18:30 every day (Figure 5), and turn off the load at 23:20 every day (Figure 6). If you want to cancel this group, you can press the "RESET/RECALL" button to delete this group of time settings. At this time, the group of time will be reset to the initial state, that is, "--: --" (Figure 2 and Figure 3). Under certain conditions (without any key operation or switching to other interfaces within 20 seconds after cancel operation), just press the "RESET/RECALL" button again to restore this group of time settings.

Step 5. AUTO/MANU

The timer switch has two switching modes: automatic and manual. In the automatic mode, the timer switch will be set according to the timing of steps 1 to 3, and the load will be automatically turned on or off at the corresponding time without human intervention. In manual mode, the load must be turned on or off by manual adjustment.
The specific operations are as follows:
1) If you need to turn on the load manually, you can click the "AUTO/MANU" button to switch the "▼" symbol on the display to the "ON" position (Figure 6). At this time, the load will always be in the on state and cannot be turned off automatically.
2) If you need to turn off the load manually, you can click the "AUTO/MANU" button to switch the "▼" symbol on the display to the "OFF" position (Figure 7). At this time, the load will always be in the off state and cannot be turned on automatically.
3) If you need to switch the load automatically, you can click the "AUTO/MANU" button to switch the "▼" symbol on the display to the "AUTO" position (Figure 8). At this time, the working state of the load will be switching automatically according to the timing setting, without being interfered by humans.

Timing Setting image How to set the mode of timer switches

Timing Setting 2

Step 6. Lock and unlock

For the timer switch with button lock (or keyboard lock), you can quick press the "RESET/RECALL" key four times to lock or unlock all the buttons.
-How to lock the buttons?
In the unlocked state, quick press the "RESET/RECALL" button four times or without any operation within 30 seconds to lock all the buttons (Figure 9). At this time, there will be a "∂" symbol in the bottom left, and you cannot make any settings for the timer switch.
-How to unlock buttons?
In the locked state, quick press the "RESET/RECALL" button four times to unlock all the buttons (Figure 10), and you can make settings at this time.

When you think there is a fault (FAQs)


Note: When the product fails, please disconnect the power first, and then check the equipment!
1 Check the week
If the timer switch does not turn on or turn off the load at the set time, it may be that the "WEEK" is not adjusted correctly, please check or reset it according to the method introduced in "Timing Setting".
2 Check the time groups
If the first point is confirmed to be correct, but the load still cannot be switched correctly on time, the reason will be that the extra time group has not been cancelled. Please refer to the method introduced in "Timing Setting" to delete it. PS: Only when the display shows "--: --", it means the time group is deleted successful; if it displays "00:00", it means 0 o'clock (24 o'clock), not the deleting success.
3 Check the switching mode
If the above two points are confirmed to be correct, but the timer switch still does not work normally, it may be that the timer switch is working in "Manual Mode". You can first adjust the "AUTO/MANU" key to set the timer switch to the right working state of the load (ON or OFF), then switch to the "Automatic Mode".
4 Check the fuse
If the above three points are correct and the timer switch still cannot work normally, please open the rear seat insurance cover (terminal cover) and check whether the fuse has been blown. If it is blown, please replace with a new 0.1A~0.3A fuse.
5 Check the power supply
If the Work LED (or Output LED) is on when the timer switch is working, but the load cannot be switched normally, please check whether the voltage of the power supply is too low. If the timer switch is burned out, please check whether the power supply voltage exceeds the rated voltage of the product and whether the power cable is connected incorrectly.
6 Please replace the battery
If the LCD screen does not display or the display is not clear, replace the battery with the same specification. (Only for timer switch with replaceable batteries)
7 Please contact us or local distributor
If the fault cannot be eliminated by the above methods, please contact us or the distributor (dealer) in your local area.

Attentions


1 For those equipment (such as medical equipment and large equipment, etc.) that may cause life safety accidents or cause major harm to society due to the error of the timer switch, please do not choose this timer switch.
2 For those equipment (large heaters or cold storage, etc.) that may cause major property losses due to the error of the timer switch, ensure that there is sufficient design margin when using this timer switch, and take safeguard measures such as the double protection circuit.
3 Do not repair, disassemble or modify this timer switch by yourself. If you need to repair and check it, please be sure to entrust a dealership or other authorized unit.
4 Do not touch any terminal on the timer switch after it powered on.
5 This timer switch cannot work in humid, corrosive and high metal content gas environment. And do not let the timer switch come into contact with oil or water.


  Get in touch with us now!


Please take a minute or two to complete this simple form to get reply in 24 hours, thank you!

*Please check the trash box of your mailbox, if you do not receive our email.